Electrochemical Simulation Package
ESP

Electrochemical Simulation Package (ESP) is a program to perform general electrochemical simulation of pulse voltammetric techniques, and best fitting of experimental data at solid and DME electrode. Available techniques are:

  • Cyclic Voltammetry (CV)
  • Square Wave Voltammetry (SWV)
  • ChronoAmperometry (CA)
  • Sampled DC Polarography

The simulated mechanism can be build as combination of:

  • maximum of 20 species
  • maximum of 10 chemical reactions
  • maximum of 10 redox couples

Routine to evaluate Uncompensated Resistance (RU) and Double Layer capacitance (DL) effects is included.

The best fitting routine allow you to define, formally, inside experimental data points, a maximum of 10 ranges. The best fitting is performed over only such ranges.

ESP has the same look of software Model 270 by EG&G. Most of M270 parameters are commonly employed in ESP with the same meaning. ESP simulate a "digital" potentiostat (like EG&G 273) rather than an "analog" one (i.e. Stair Case Voltammetry intead of CV). ESP can directly read and write both M270 and general input/output ASCII files. ASCII input/output files can be used by non EG&G users.

Contact: Carlo Nervi, E-mail: nervi@chpc06.ch.unito.it,

The full on-line html manual is available at http://chpc06.ch.unito.it/esp_manual.html



NetSci, ISSN 1092-7360, is published by Network Science Corporation. Except where expressly stated, content at this site is copyright (© 1995 - 2010) by Network Science Corporation and is for your personal use only. No redistribution is allowed without written permission from Network Science Corporation. This web site is managed by:

Network Science Corporation
4411 Connecticut Avenue NW, STE 514
Washington, DC 20008
Tel: (828) 817-9811
E-mail: TheEditors@netsci.org
Website Hosted by Total Choice